Products

Newly enhanced technology meets practice needs and patient profiles

Source: Getty Images. This is not an actual patient. Results may vary.

VenaCure 1470 Pro Laser

As a water-specific laser, the VenaCure 1470 Pro laser targets water as the chromophore to absorb the laser energy. Since vein structure is mostly water, it’s theorized that the 1470 nm laser wavelength efficiently heats endothelial cells with a low risk of collateral damage, resulting in an optimal vein ablation1.

The VenaCure 1470 Pro laser is designed to work exclusively with AngioDynamics fibers, including NeverTouch fibers. Maximizing these two technologies can result in even better patient outcomes1. The 1470 nm laser allows effective vein ablation with the targeted energy of 30-50 joules/cm at a setting of 5-7 watts.

Refer to the Operator’s Manual and Directions for Use/Instructions for Use for complete instructions, warnings, and precautions. Click here for full risk information.

  • Streamlined form factor fits the modern practice environment, and it’s compact enough to transport between hospital and office
  • Intuitive touch-screen enhances usability
  • Quick and easy preset laser adjustments can suit individual preferences in multiple-practitioner practices and treatment types

Easy to use

  • Intuitive touch-screen interface
  • Programmable sound pulses allow for audible tracking of pull-back rate, which increases repeatability of treatment
  • Aiming the beam with variable modes and brightness increases visibility in patient
  • Real-time, on-screen display of treatment energy

Dependable quality

  • Industry-leading, three-year standard warranty ensures every laser receives top-notch service
  • Internal sensors constantly monitor wattage, ensuring a constant energy output

Proprietary fibers in convenient procedure kits

NeverTouch Gold-Tip Fiber Procedure Kits

The NeverTouch Gold-Tip Laser Fiber, exclusive to AngioDynamics, helps minimize pain and bruising , while enhancing visibility and ease of use 1.

Benefits:

  • Innovative design eliminates laser tip contact with the vein wall, minimizing damage to the wall as compared to traditional bare-tip fibers.
  • Gold-tip maximizes ultrasonic visibility, making it easier for physicians to use.

Refer to the Operator’s Manual and Directions for Use/Instructions for Use for complete instructions, warnings, and precautions. Click here for full risk information.

NeverTouch Direct Procedure Kits

The NeverTouch Direct Fiber includes an atraumatic tip for sheathless placement, which allows physicians to advance to the saphenofemoral junction in appropriate patients without using a TRE-Sheath introducer.

Benefits:

  • In addition to the benefits of the NeverTouch Gold-Tip Fiber, the NeverTouch Direct Procedure Kit allows physicians to gain access, advance the fiber, and treat a diseased vein without placing a second guidewire. This results in faster procedures with fewer components.

Refer to the Operator’s Manual and Directions for Use/Instructions for Use for complete instructions, warnings, and precautions. Click here for full risk information.

400 Micron Accessory Vein Ablation Kit

Incompetent Perforator Veins (IPVs) associated with Chronic Venous Insufficiency (CVI) are linked to venous hypertension, severe sequelae of CVI, and the development of leg ulcers. Treatment of IPV and CVI can lead to reduced recurrent rates for venous ulcers 4. The 400 Micron Accessory Vein Ablation Kit’s low-profile fiber allows for simple access and accurate positioning.

Benefits:

  • Smaller-sized fiber aids in Saphenous Vein (SV) access and positioning.
  • 21G venous access needle ensures easy, atraumatic access.
  • .018” guidewire navigates small, tortuous veins with a floppy tip and has a firm anchor to guide the sheath and hold it in place.

Refer to the Operator’s Manual and Directions for Use/Instructions for Use for complete instructions, warnings, and precautions. Click here for full risk information.

Spotlight OPS Procedure Kits

Spotlight OPS Procedure Kits eliminate the need for a separate dilator and provide a cost-effective alternative to other products.

Benefits:

  • Tungsten-loaded sheath tip increases echogenicity, allowing for bright and easy tip placement, while the smooth, soft, atraumatic tip and low profile make it easy to navigate.
  • Unique self-dilation technology eliminates the need for a separate dilator, resulting in fewer components, fewer exchanges, and potentially faster procedures.

Refer to the Operator’s Manual and Directions for Use/Instructions for Use for complete instructions, warnings, and precautions. Click here for full risk information.

Procedure Packs

Everything today’s providers need to perform venous ablation with the precision of the VenaCure EVLT system. Find a kit to suit your needs with four options available:

  • Premier Procedure Pack
  • Basic Procedure Pack
  • Standard Procedure Pack
  • Phlebectomy Procedure Pack 

†Compared to other procedural factors, i.e., wavelength alone.

References

  1. Kabnick L, et al. Fiber type as compared to wavelength may contribute more to improving postoperative recovery following endovenous laser ablation. JVS. 4:286-92.
  2. Caliskan K, Cakmakci E, Celebi I, Basak M. Endovenous 1470 nm laser treatment of the saphenous vein: early report of pain assessment. Journal of Cardiovascular Surgery. 2013;54(2):p.263-7.
  3. Schwarz T, Hodenberg EV, Furtwängler C, Rastan A, Zeller T, Neumann F-J. Endovenous laser ablation of varicose veins with the 1470-nm diode laser. Journal of Vascular Surgery. 2010;51(6):1474-1478. doi:10.1016/j.jvs.2010.01.027.
  4. Barwell J, Davies C, Deacon J. Comparison of surgery and compression with compression alone in chronic venous ulceration (ESCHAR study): Randomized controlled trial. ACC Current Journal Review. 2004;13(8):23-24. doi:10.1016/j.accreview.2004.07.117.